Skip to main content
AI Crawler DoS Attacks | Dataverse Creation Restriction – Please note:
  • We are experiencing a coordinated attack by AI training crawler bots, which slow down the service. We are working on mitigating the problem and apologize for any inconveniences.
  • Institutional or project level dataverses have to be created with confirming permissions. See details in guide.
Jülich DATA (Forschungszentrum Jülich GmbH)
Metrics
168,023 Downloads
Featured Dataverses

In order to use this feature you must have at least one published dataverse.

Publish Dataverse

Are you sure you want to publish your dataverse? Once you do so it must remain published.

Publish Dataverse

This dataverse cannot be published because the dataverse it is in has not been published.

Delete Dataverse

Are you sure you want to delete your dataverse? You cannot undelete this dataverse.

Find Advanced Search

201 to 210 of 20,030 Results
MS Excel Spreadsheet - 15.1 MB - SHA-256: 03bcb7ad6b0a138bbf2636e6a135796fc331f6585c40b8bd781885bb72e7fcc2
The system is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file contains the corresponding measured data recorded during operation of the set-point profile, which defines a trajectory of...
MS Excel Spreadsheet - 285.5 KB - SHA-256: 729cc9bb2d60ae41d25061393534ab482f93c112a76bf83714fb235921829a1b
The 100 kW Proton Exchange Membrane (PEM) electrolyzer is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file contains the set-point profile, which defines a trajectory of a Kombi-PV-Profi...
MS Excel Spreadsheet - 14.9 MB - SHA-256: 250edd4603c94482ceff111bd2f2c5de5087edc69c52b7b0b15240d7ddc98989
The system is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file contains the corresponding measured data recorded during operation of the set-point profile, which defines a trajectory of...
MS Excel Spreadsheet - 191.5 KB - SHA-256: f5ceaccc71405a74c960c226a34365fe2643bf15f723bf46dc77eb58b05420f9
The 100 kW Proton Exchange Membrane (PEM) electrolyzer is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file contains the set-point profile, which defines a trajectory of a Kombi Current...
MS Excel Spreadsheet - 5.0 MB - SHA-256: 34fff28e46c196ed669c3ef627a3247a62abf1e4db3a30c1255d1ed63d3c799e
The system is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file contains the corresponding measured data recorded during operation of the set-point profile, which defines a trajectory of...
MS Excel Spreadsheet - 207.5 KB - SHA-256: 8dced6487f2e39322193d50139c65a0d3baef12ee0b609fb9072491bff29da28
The 100 kW Proton Exchange Membrane (PEM) electrolyzer is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file contains the set-point profile, which defines a trajectory of a Kombi Current...
MS Excel Spreadsheet - 3.5 MB - SHA-256: 362f3f97fb3c21643363be3540b7caea16afba07e6e2ca4139dcc13493421e3f
The system is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file contains the corresponding measured data recorded during operation of the set-point profile, which defines a trajectory of...
MS Excel Spreadsheet - 206.0 KB - SHA-256: a4718f0c88b1958b3394baedcd13996a60f0d4a8044b137201fccc95b779df5c
The 100 kW Proton Exchange Membrane (PEM) electrolyzer is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file contains the set-point profile, which defines a trajectory of a Kombi Current...
MS Excel Spreadsheet - 13.3 MB - SHA-256: 6af704eecd51bf5257edbab24e44b401b2e99fd045b1767222f1254d98f5283c
The system is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file contains the corresponding measured data recorded during operation of the set-point profile, which defines a trajectory of...
MS Excel Spreadsheet - 189.0 KB - SHA-256: d439f180f1bbfb39fab34c4857dfcaf84637e42891275c41e0cd6ddfbd47f7bb
The 100 kW Proton Exchange Membrane (PEM) electrolyzer is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file contains the set-point profile, which defines a trajectory of a Kombi Current...
Add Data

Log in to create a dataverse or add a dataset.

Share Dataverse

Share this dataverse on your favorite social media networks.

Link Dataverse
Reset Modifications

Are you sure you want to reset the selected metadata fields? If you do this, any customizations (hidden, required, optional) you have done will no longer appear.

Contact Jülich DATA Support

Jülich DATA Support

Please fill this out to prove you are not a robot.

+ =