31 to 40 of 19,042 Results
Aug 15, 2025 -
JART v-ECM v1
SVG Image - 563.5 KB - SHA-256: e8ced5836ba74af09e38ac51313c2061a7aef7697b7e94c37d2d5f99d4a97bfd
[2] The experimentally measured threshold switching kinetics data points of a Ag-HfO2-Pt ECM device stack together with their d2d variability are displayed in red, whereas the simulated ones with their d2d variability are displayed in blue. |
Aug 15, 2025 -
JART v-ECM v1
SVG Image - 20.9 MB - SHA-256: b8e0c44689a90ae87c7470684765ef9220ff2b618c22ce324442338db61e51b2
[3] (a) The applied voltage signal to a Ag-HfO2-Pt ECM device stack in the measurement and in the simulation in order to investigate the device’s relaxation behavior: The 1 ms programming/write pulse of Vp is followed by a read voltage Vread = 0.1 V. The inset shows that the sign... |
Aug 15, 2025 -
JART v-ECM v1
Unknown - 10.9 KB - SHA-256: 6b8b1f93751a06906990947252b9f60dc833dd5718cc65e6a1362792816b7201
JART ECM v1 volatile |
Aug 15, 2025 -
JART v-ECM v1 var
SVG Image - 996.7 KB - SHA-256: e05d35a6ca3c658a0b666d197f06274eedd3345bb03f215fe47638d111116a64
[1] (a) 30 cycles of measured I-V sweeps of a Ag-HfO2-Pt ECM device stack are shown. A c2c variability is visible. (b) 30 cycles of simulated I-V sweeps are shown through the usage of the variability-aware volatile ECM model. For both, measurement and simulation, the device switc... |
Aug 15, 2025 -
JART v-ECM v1 var
SVG Image - 563.5 KB - SHA-256: e8ced5836ba74af09e38ac51313c2061a7aef7697b7e94c37d2d5f99d4a97bfd
[2] The experimentally measured threshold switching kinetics data points of a Ag-HfO2-Pt ECM device stack together with their d2d variability are displayed in red, whereas the simulated ones with their d2d variability are displayed in blue. |
Aug 15, 2025 -
JART v-ECM v1 var
SVG Image - 20.9 MB - SHA-256: b8e0c44689a90ae87c7470684765ef9220ff2b618c22ce324442338db61e51b2
[3] (a) The applied voltage signal to a Ag-HfO2-Pt ECM device stack in the measurement and in the simulation in order to investigate the device’s relaxation behavior: The 1 ms programming/write pulse of Vp is followed by a read voltage Vread = 0.1 V. The inset shows that the sign... |
Aug 15, 2025 -
JART v-ECM v1 var
Unknown - 17.1 KB - SHA-256: 042e2482fd5de9844011af4607afe6083a0b7348aea442ec92f2dea8a8353bf2
|
Aug 12, 2025 -
Data used in: Coverage-dependent electronic and geometric structure of sexithiophene on Cu(110)-p(2x1)O
TIFF Image - 2.0 MB - SHA-256: 7df41dd6bece85a566c644b48e04ce310feb44e1286bb0ee828588b4c37fb75f
|
Aug 12, 2025 -
Data used in: Coverage-dependent electronic and geometric structure of sexithiophene on Cu(110)-p(2x1)O
Unknown - 9.1 KB - SHA-256: 60bea34c27a3b73f3ce869d219285b5836d17b4b676f28dfdac63adb74503840
|
Aug 12, 2025 -
Data used in: Coverage-dependent electronic and geometric structure of sexithiophene on Cu(110)-p(2x1)O
TIFF Image - 2.0 MB - SHA-256: 9f2962b2b149722a192470b7eed9acfc06f4154cc7794382a1b27618ef72eda7
|