Skip to main content
AI Crawler DoS Attacks | Dataverse Creation Restriction – Please note:
  • We are experiencing a coordinated attack by AI training crawler bots, which slow down the service. We are working on mitigating the problem and apologize for any inconveniences.
  • Institutional or project level dataverses have to be created with confirming permissions. See details in guide.
The dataverse of the Institute of Energy Technologies – Electrochemical Process Engineering (IET-4)
Featured Dataverses

In order to use this feature you must have at least one published dataverse.

Publish Dataverse

Are you sure you want to publish your dataverse? Once you do so it must remain published.

Publish Dataverse

This dataverse cannot be published because the dataverse it is in has not been published.

Delete Dataverse

Are you sure you want to delete your dataverse? You cannot undelete this dataverse.

Find Advanced Search

541 to 550 of 831 Results
MS Excel Spreadsheet - 11.0 MB - SHA-256: fbf8475316e45e81401733ae2eb0d6edc51b96dc9e5416f56fbd057d1555299b
The system is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file contains the corresponding measured data recorded during operation of the set-point profile, which defines a trajectory of...
MS Excel Spreadsheet - 669.5 KB - SHA-256: 67a1ca13a679f331e92cda8f1c2d7cda4b79dfe29a8f9e53dfbea239ab975b58
The 100 kW Proton Exchange Membrane (PEM) electrolyzer is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file contains the set-point profile, which defines a trajectory of dynamic ramping...
MS Excel Spreadsheet - 1.8 MB - SHA-256: 774e153791bdc09a7040fea67c7f69f3962ff4234f645a236271f36d46c6799d
The system is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file contains the corresponding measured data recorded during operation of the set-point profile, which defines a trajectory of...
MS Excel Spreadsheet - 5.7 MB - SHA-256: e757c4f7da53522aa123c568009de61be9861432c2a996dbae906f3a239ea0f2
The system is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file contains the corresponding measured data recorded during operation of the set-point profile, which defines a trajectory of...
MS Excel Spreadsheet - 2.4 MB - SHA-256: 2ba84bf01e4316dca2db6d76138d66b8138f18597e7adfd6ec6e7d9496f14c8f
The system is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file contains the corresponding measured data recorded during operation of the set-point profile, which defines a trajectory of...
MS Excel Spreadsheet - 675.5 KB - SHA-256: 781cb766c32d71adc45b981f3ffe2f5b2a439bcc2d0ea271df8698bfc9500040
The 100 kW Proton Exchange Membrane (PEM) electrolyzer is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file defines the set-point profile, specifying the trajectory of dynamic ramping co...
MS Excel Spreadsheet - 675.5 KB - SHA-256: 7ea906fc35fd2771dfb65a14fc005fd101499d8d51f885d3d25ac69ede366e35
The 100 kW Proton Exchange Membrane (PEM) electrolyzer is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file defines the set-point profile, specifying the trajectory of dynamic ramping co...
MS Excel Spreadsheet - 692.0 KB - SHA-256: d3b23f3a89aa1b012c68b57317a6a4c8b7e8e0af83753af48562bb9e531ff2a4
The 100 kW Proton Exchange Membrane (PEM) electrolyzer is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file defines the set-point profile, specifying the trajectory of dynamic ramping co...
MS Excel Spreadsheet - 13.8 MB - SHA-256: 3fbed63e2978fd632b425d23570363fa26a053c4e86475f769d4f1c774f1a41f
The system is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file contains the corresponding measured data recorded during operation of the set-point profile, which defines a trajectory of...
MS Excel Spreadsheet - 692.0 KB - SHA-256: fdd6e54019a45880f5167abeffe5e79836845c3800568a095a2c8d27247e28ac
The 100 kW Proton Exchange Membrane (PEM) electrolyzer is operating under normal conditions, with all set-points defined by a predefined set-point profile executed through a control sequence. This file defines the set-point profile, specifying the trajectory of dynamic ramping co...
Add Data

Log in to create a dataverse or add a dataset.

Share Dataverse

Share this dataverse on your favorite social media networks.

Link Dataverse
Reset Modifications

Are you sure you want to reset the selected metadata fields? If you do this, any customizations (hidden, required, optional) you have done will no longer appear.

Contact Jülich DATA Support

Jülich DATA Support

Please fill this out to prove you are not a robot.

+ =