41 to 50 of 447 Results
Mar 25, 2025
Menzel, Stephan; Bengel, Christopher, 2025, "JART ECM v1", https://doi.org/10.26165/JUELICH-DATA/4F3ITW, Jülich DATA, V1
The JART ECM v1 model describes the switching dynamics of Electrochemical Metallization Cells, which are also known as Conductive Bridge RAM (CBRAM) or atomic switches. The model includes the redox-reactions at the metal insulator interfaces, ion hopping transport, and the electr... |
Mar 25, 2025 -
JART ECM v1
JPEG Image - 100.4 KB - SHA-256: e47bd74017eb26c9eeb9f66304cfe0090420a71670ba04caebdc76fc280b8442
Ionic and Electronic process included in the JART ECM v1 model. |
Mar 25, 2025 -
JART ECM v1
Unknown - 11.2 KB - SHA-256: cff0f397eb1db8e6d222f073133c4874991b8238eb044059a87f211c6241cfc8
The Verilog-A code of this model |
Mar 25, 2025
Menzel, Stephan; Bengel, Christopher, 2025, "JART VCM v1", https://doi.org/10.26165/JUELICH-DATA/TQOP7I, Jülich DATA, V1
Short description: The JART VCM v1 model was developed to simulate the switching characteristics of devices based on the valence change mechanism (also called OxRAM). In this model, the ionic defect concentration (oxygen vacancies) in the disc region close to the active electrode... |
Mar 25, 2025 -
JART VCM v1
JPEG Image - 39.7 KB - SHA-256: 19d125ff33876fe006dd0b31ed1681bcb32031ee2f623cc2b1031811eefa746a
Equivalent circuit diagram of the JART VCM v1 model. |
Mar 25, 2025 -
JART VCM v1
JPEG Image - 220.5 KB - SHA-256: b5bdc35559bd4f836c1c8955f2a592caa96fbf332272569cfc19c33bc5b14d57
Highly voltage-dependent characteristic numbers of SET pulse switching, obtained with both experiments and simulations [3]. The simulation differs from the published result in [1] regarding the parameters, the definition of the criteria, and Eqs. (3.5), (3.7) to (3.10) and (3.12)... |
Mar 25, 2025 -
JART VCM v1
Windows Executable - 1.8 MB - SHA-256: 7af0ec0d17ff79bacd9c1fd78e64f716628b35ad91d97d1cfbb6b64aa3f2c0c5
Standalone MATLAB App |
Mar 25, 2025 -
JART VCM v1
Unknown - 6.4 KB - SHA-256: 264dee543a8f4e9b2aaf1e6dbb60e619ef0a6938675445250b2ce8820d0b88a5
The Verilog-A code of this model |
Mar 25, 2025 -
JART VCM v1
JPEG Image - 158.4 KB - SHA-256: c92bb68722f7283e080f5dd4841c4a50b6abf450822d3968860b85e3c8348cf5
Parameter set for STO |
Mar 25, 2025
Menzel, Stephan; Bengel, Christopher, 2025, "JART VCM v1b", https://doi.org/10.26165/JUELICH-DATA/LUA8QY, Jülich DATA, V1
The JART VCM v1b var model represents an extension of the JART VCM v1b model which additionally considers device-to-device and cycle-to-cycle variability. The ECD can be seen in Fig. 1. The physical equations are the same as in the v1b model. Device-to-device variability is achie... |